Back to publication

Back to Figures


Figure C– Summary of Inverse Age of Air Values

House conditions

Wind speed

(m/s)

Inverse age of air (h-1)

KLA

MBED

BED2

BED3

All fans off

0

0.16

0.17

0.18

0.18

5

0.17

0.19

0.18

0.19

Forced-air fan on; all exhaust fans off; interior doors open

0

0.19

0.19

0.19

0.19

5

0.53

0.53

0.52

0.52

Forced-air fan on; all exhaust fans off; interior doors closed

0

0.24

0.24

0.24

0.24

5

0.55

0.55

0.57

0.57

Intake on forced-air return; interior doors open

0

0.32

0.32

0.32

0.32

5

0.63

0.64

0.62

0.63

Intake on forced-air return; interior doors closed

0

0.38

0.38

0.38

0.38

5

0.65

0.63

0.65

0.65

Whole house exhaust in KLA zone; passive inlet vents; interior doors open

0

0.40

0.37

0.31

0.35

5

0.55

0.42

0.39

0.44

Whole house exhaust in KLA zone; passive inlet vents; interior doors closed

0

0.40

0.33

0.31

0.35

5

0.55

0.41

0.39

0.44

Whole house exhaust in BATH1 zone; passive inlet vents; interior doors open

0

0.40

0.37

0.31

0.35

5

0.54

0.42

0.39

0.44

Whole house exhaust in BATH1 zone; passive inlet vents; interior doors closed

0

0.39

0.32

0.30

0.30

5

0.51

0.39

0.39

0.41

Whole house exhaust in KLA zone; no passive inlet vents; interior doors open

0

0.36

0.33

0.28

0.32

5

0.47

0.37

0.31

0.37

Whole house exhaust in KLA zone; no passive inlet vents; interior doors closed

0

0.36

0.29

0.27

0.30

5

0.47

0.34

0.30

0.36

All values correspond to 20 °C (36 °F) temperature difference.
The values for nonzero wind speed are averages over winds from the north, south, east and west.