Figure B-2 – Summary of Annual ACH at Heating and Cooling

Case/Condition

ALBANY

MIAMI

SEATTLE

Mean air change rate (h-1)

Percent of hours < 0.25 h-1

Percent of hours < 0.35 h-1

Mean air change rate (h-1)

Percent of hours < 0.25 h-1

Percent of hours < 0.35 h-1

Mean air change rate (h-1)

Percent of hours < 0.25 h-1

Percent of hours < 0.35 h-1

1/Envelope leakage only

0.27

39

83

0.14

100

100

0.23

67

99

2/Scheduled exhaust fans

0.32

33

71

0.19

87

89

0.27

57

84

3/Forced-air operating on outdoor temperature

0.42

13

38

0.29

64

87

0.36

17

66

4A/Intake on forced-air, operating on outdoor temperature

0.46

10

28

0.31

49

87

0.38

13

52

4B/Intake on forced-air, occupancy schedule

0.64

4

11

0.49

20

46

0.58

4

18

5A/Passive inlets and whole house exhaust on exhaust schedule

0.49

6

25

0.35

30

82

0.43

6

42

5B/Passive inlets and whole house exhaust on occupancy schedule

0.57

2

9

0.41

10

56

0.52

2

11

6A/ Whole house exhaust (no inlets) on exhaust schedule

0.44

13

39

0.31

64

87

0.38

17

66

6B/ Whole house exhaust (no inlets) on occupancy schedule

0.53

5

15

0.37

30

65

0.48

6

23