Table 9. Observations Of Annual Simulation Results For
Las Vegas
Las Vegas, Nevada | |
Simulation Description | Observations Of Results |
Reference case | (R-28 ceiling, 1:150 vented attic, ducts in attic, no duct leakage, R-19 walls, double glazing) |
Sealed R-40 sloped | Good for cooling, excellent for heating |
White tile, sealed R-28 sloped | Excellent for cooling, no difference for heating |
Ducts in conditioned space | Always good |
Sealed R-28 sloped | No difference for cooling, very good for heating |
White tile | Very good for cooling, penalty for heating due to reduced solar heat gain |
1:300 Attic vent | Very little net difference from 1:150 reference case |
Sealed R-40 flat | Penalty on cooling, saves on heating, nets essentially the same as reference case |
Sealed R-28 flat | Not recommended |
Duct leak 10% ret 5% sup | Never good |
Duct leak 15% ret 10% sup | Never good |