Back to publication


Table 4. Daily and total energy use for electric heating monitoring period

Frame House

Panel House

Regression model = a0*lhor + a1(Tin-Tout)+a2

number
of days

avg daily
energy-use
kwh/day

max daily
energy-use
kwh/day

total heat
energy-use
kwh

avg daily
enegy-use
kwh/day

max daily
energy-use
kwh/day

total heat
energy-use
kwh

% diff
total heat
energy-use

Electric Heating Monitoring
Measured data, Julian days 25-41

17

37.0

52.6

629

31.4

46.1

533

15.2%

Measured data applied to reg. model, JD 25-41

17

36.6

50.6

623

31.5

43.9

536

14.0%

TMY data applied to reg. model, JD 25-41

17

46.8

70.7

795

39.3

61.2

668

16.0%

TMY data applied to reg. model, Nov-Mar

151

34.8

84.5

5253

29.1

73.0

4395

16.3%

Measured weather data to DOE2, JD 25-41

17

501

478

4.6%

TMY data to DOE2, JD 25-41

17

812

747

8.0%

TMY data to DOE2, Nov-Mar, actual ACH

151

5040

4670

7.3%

TMY data to DOE2, Nov-Mar, 0.35 ACH

151

5385

5269

2.2%

Back to publication