Home / current data / Stalwart Built Near Zero Energy Home

Case Study: Stalwart Built Near Zero Energy Home

Callaway, Florida

ZEP Home
Stalwart Built Near Zero Energy Home
(Photo: John Sherwin)


This near zero energy home (NZEH) by Promise Land Builders was built with technical assistance from BAIHP through a partnership with Stalwart Built Homes.  Stalwart Built Homes provide participating builders with high performance modular building systems that are designed and constructed with the Building America systems engineering approach.  The building systems, combined with builder training activities, enable builders to overcome technical, quality, and economic challenges encountered with high performance housing.

Home Profile Available at www.MyFloridaGreenBuilding.info



Eric Martin (right) describes the Building America program during a Stalwart Built Homes builder training. (Photo: Neil Moyer)





This 1371 sqft, three bedroom “Nashville” model home is the first home in Florida to achieve LEEDTM Platinum certification, the highest certification level a home can reach through the U.S. Green Building Council’s (USGBC) LEED for Homes program.  This program rewards performance in a variety of environmental areas including sustainable sites, water efficiency, energy and atmosphere, materials and resources, indoor environmental quality, and homeowner awareness.   




             

info mon A datalogger was installed in late August 2008 and data collection is ongoing. See a summary of current data at the InfoMonitors web site. A detailed data interface is also available where graphs can be produced like those used in this case study. wg logo


Dennis Stroer
Dennis Stroer of Calcs-Plus measures mechanical ventilation flow on the Stalwart NZEH.
(Photo: Neil Moyer)

Some features of the Stalwart Built Homes NZEH include:

  • 3.6 kW photovoltaic system
  • Closed loop Geothermal heating and cooling unit with
    supplemental dehumidification
  • Desuperheater providing hot water with waste heat from
    geothermal unit
  • Low-e windows (U = 0.32, SHGC = 0.29)
  • Spray foam insulation under roof deck and under crawlspace floor
  • Ductwork inside home’s air and thermal barrier
  • Reflective metal roof
  • Energy Star appliances
  • Compact fluorescent lighting throughout
  • Sustainable and low-emitting interior finishes
  • HERS Index = 26

 



graph

 

The modular construction process allows for most of the construction to take place in a controlled factory environment.
(Photo: Carlos Colon)
Chases were installed in the factory to accommodate
wiring for the solar and data monitoring systems.
(Photo: Carlos Colon)